Intelligent switch module

date 2023-01-05     author: admin     view:472

12.jpg


Overvoltage protectionThe overvoltage alarm value (235V-265V) can be set by itself, and when the voltage is higher than the overvoltage alarm value, the device will push an alarm message. When the voltage exceeds 275V, the switching module is automatically disconnected.
Undervoltage protectionThe undervoltage alarm value (175V-205V) can be set by itself, and when the voltage is lower than the undervoltage alarm value, the device will push the alarm message. When the voltage is lower than 160V, the switching module is automatically disconnected.
Over-temperature protectionWhen the terminal temperature exceeds 75°C, the device will push alarm information. Above 80°C for 15s, the switch module will be automatically disconnected.
Overload protectionThe line setting current can be customized within the rated current range; When the current of the current line is greater than the setting current, the device will push an early warning message. When the current current is greater than 1.1 times the setting current, the switch module will automatically disconnect.
Leakage protectionWhen the 1P+N switching module detects that the residual current value reaches 20mA, it will automatically turn off within 0.04s.
Lock functionOn the handheld power APP line details page, "Lock Manual" can be enabled, after locking, the line cannot be closed locally.
Remote controlRemote switch operation through mobile app and web management platform.
Timing controlSet one or more timing to the line to realize automatic switch control.
Energy meteringThe switch module can measure the power consumption of the line, and the current and historical power consumption of each line can be viewed through the mobile app and web management platform.
Share the deviceThe same device can be shared with others for common use (up to 5 shares on the same device), and administrators can assign permissions to the people who share it.
Operational logsRecords the actions of all users corresponding to the device. Including: switching lines, executing scenes, adding timing, and other operations.
Fault alarmWhen an early warning and fault are generated, the device will push the alarm information to the cloud, and the push message can be received through the mobile app and web management platform. The alarm information contains the fault location and occurrence time.
ProfileMultiple scenarios can be set to switch and switch multiple lines with one click (can be set across gateways).
Data viewingYou can view the current voltage, current, power, temperature, leakage current, energy and other parameters of each line.